Home > Ecc Error > 3ware Ecc Error

3ware Ecc Error

Contents

So, I'm thinking that we can disregard the ECC-ERRORS reported by the 3ware card. –Stefan Lasiewski Jun 28 '13 at 2:47 add a comment| Your Answer draft saved draft discarded I replaced a failed drive in a RAID yesterday. The cache synchronization was not successful for some reason. 0062 Enclosure removed Event Type: Warning Cause: Applies only to the 9690SA controller. I've run RAID 5 for years and never had a rebuild fail. http://caterace.com/ecc-error/3ware-error.html

like 10 dead out of 15 drives on 5 different machines in the past 6 months.. If the temperature falls outside the acceptable range then comes back within the acceptable range, this AEN will be posted to the host. 04Ah Battery temperature is low The Battery Backup For information on replacing a fan, see your enclosure documentation or contact your enclosure manufacturer. 8002 Enclosure fan removed Event Type: Warning Cause: Applies only to the 9690SA controller. permalinkembedsavegive gold[–]hateexchangeatheist, unless restoring backups[S] 0 points1 point2 points 2 years ago(2 children)Sounds good. http://serverfault.com/questions/332935/what-does-3wares-tw-cli-mean-by-a-degraded-disk-vs-ecc-error

3ware Degraded Drive

One of the enclosure power supplies is not working. However, if the temperature is very cold, condensation can occur and cause media errors and damage. However, if the temperature is very cold, condensation can occur and cause media errors and damage. And now to top it off: MY FRICKING BACKUP IS DEAD!

Get 1:1 Help Now Advertise Here Enjoyed your answer? If it has failed, replace it. This may be a fault in the BBU control module. Tw_cli Ignoreecc The enclosure temperature is now back within the acceptable range.

more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed However, due to ATA drives' ability to reallocate sectors on write errors, the rebuild failure is most likely caused by the source drive of the rebuild detecting some sort of read Possible causes of drive time-outs (also known as ATA-Port time-outs) include a bad or intermittent disk drive, power cable or interface cable. So whatever you had occur should have never occurred.

This message is posted when the result of the health test is below the warning threshold. Tw_cli Cheat Sheet They are a few sectors too small. The factors here are the number of disks in the array, the amount of data to backup/restore and how much XANAX i have on hand. The enclosure temperature is below the enclosure manufacturer’s specified operating temperature.

Hard Drive Ecc Error

You can pause it, however, by scheduling it to take place during off-hours. Read More Here The enclosure is reporting that it is unable to determine the temperature of the unit. 3ware Degraded Drive ZFS does not currently detect any errors. Tw_cli Start Rebuild The enclosure temperature is higher than normal.

Action: Make sure that the fans are operational. check over here The controller only generates this message if the unit is missing drives for more than 20 seconds. permalinkembedsaveparentgive gold[–]Hollyweird78 1 point2 points3 points 2 years ago(4 children)That was my understanding as well. Back when 9GB was a big SCSI disk, it made sense to do RAID-5 and rebuild in 30 minutes. Tw_cli U

Also, check that your power supply is adequate for the type and number of devices attached to it. 003B Rebuild paused Event Type: Information Cause: The rebuild operation is paused. Action: This error is rare. If the system loses power or is reset without going through the normal shutdown procedure, it is possible that the data on a redundant array may be out of synchronization. his comment is here See your enclosure documentation or contact your enclosure manufacturer for more details.

kid in winter The locker problem - why squares? 3ware Degraded Ecc-error Action: Replace the battery pack. 0058 Battery capacity is below warning level Event Type: Information Cause: The measured capacity of the battery is below the warning level. Jetzt Thomas-Krenn Newsletter abonnieren Diese Seite wurde zuletzt am 18.

share|improve this answer answered Jun 27 '13 at 21:20 GioMac 3,5162929 ZFS performs integrity checks of the RAIDZ array, and it would have caught any bad sectors.

It stays at 97% rebuilt, but can't get past this error. The enclosure power supply is now back within the acceptable range. The BIOS wouldn't auto detect and manual detection resulted in a 20 GB "Maxtor LEO" drive being reported by Powermax, which failed all tests. 3ware Rebuild Stuck Remove the BBU control module from the 3ware RAID controller and the battery module from the remote card. 3.

How do you modify / Install Ubuntu? 11 91 47d Connect to MS-SQL server from Linux/PHP 8 52 20d HP Z440 RAID 1 36 29d Event ID 11: Message: The driver You may also see this message if the battery pack is plugged in while the computer is on. The Battery Backup Unit periodically evaluates the health of the battery and its ability to backup the 3ware RAID controller in case of a power failure. weblink The enclosure fan is not functioning normally and may be blocked or defective.

more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed When this event happens, the Battery Backup Unit becomes not ready and is unable to backup the 3ware RAID controller. This AEN is sent after offline unit timer expires; if the unit becomes operational before the timer expires (20 seconds) there will be no AEN since there were no IO errors. share|improve this answer answered Nov 20 '11 at 15:33 Sven♦ 66k8103145 add a comment| Your Answer draft saved draft discarded Sign up or log in Sign up using Google Sign

Do n and n^3 have the same set of digits? The user is notified of the event by this AEN. 02Dh Source drive error occurred If an error is encountered during a rebuild operation, this AEN is generated if the error kernel: 3w-xxxx: scsi3: Command failed: status = 0xc4, flags = 0x43, unit #8 Dieser Fehler wird durch ein einen Befehl verursacht, wie z.b. storage zfs hard-drive 3ware share|improve this question edited Nov 21 '14 at 18:16 asked Jun 26 '13 at 23:27 Stefan Lasiewski 12.6k2183151 Are you using the raid features of

Documents are in the WIKI. When this event happens, the Battery Backup Unit is still able to backup the 3ware RAID controller, but the user should replace the battery. 046h Battery voltage is high The Battery Only a 12% failure rate on those... Once a day, a non-destructive test is performed on the cache memory.

Today (and previously) I've run into a situation where a volume stops responding to any read or write requests. When this event happens, the Battery Backup Unit is still able to backup the 3ware RAID controller but the user should replace the battery pack if the temperature warning persists. 04Ch If you see it you may need a UPS or voltage regulator to stay within the recommended voltage range. 8042 Enclosure voltage under Event Type: Error Cause: Applies only to the A power supply may have failed.

kernel: 3w-9xxx: scsi0: AEN: INFO (0x04:0x0053): : Diese Meldung ist nicht richtig dokumentiert, deutet aber lediglich auf ein Speichergrößen Problem auf dem Server hin. For redundant arrays such as RAID 1, 10, 50, and 5, the 3ware RAID controller essentially has two copies of the users data available.